SUPERMICRO

No. Host System Minimum Host Bios
1 SUPERMICRO Super P3TDL31, SUPERMICRO Super S2DL31AMI BIOS 07.00.xx
1. 64−bit slots for 3.3v HBAs only.
Samsung

Samsung

No. Host System Minimum Host Bios
1 Samsung ES470, Samsung ES570 BIOS 3.06, EFI 1.10 [14.60], Firmware R05.21
2 Samsung ZSS150 SE7520JR23.86B.B18.03.00.0, SE7520JR23.86B.B18.03.00.0054
3 Samsung ZSS230−D, Samsung ZSS230−T SHW40.86B.D.04.00.0668
Stratus

Stratus

No. Host System Minimum Host Bios
1 Stratus ftServer 230062.0
2 Stratus ftServer 240071.0.77
3 Stratus ftServer 32101, 2, 3, 4, 5, Stratus ftServer 32201, 2, 3, 4, 5 6.0.4107, 6.0.5109
4 Stratus ftServer 43007, Stratus ftServer 460071.0
5 Stratus ftServer 52001, 3, 8, 9, 10 6.0.0, 7.0.0
1. Systems running Stratus OS 1.2.2.X or 1.3 require MS hotfix Q327477 and VxVM 2.7 Hotfix 5A. Stratus OS 1.3.1 and above incorporates these hotfixes.
2. ftServer OS 1.4.x requires PowerPath 3.0.2.
3. Bus Enumeration Issue Causes Problems using SYMCLI SCSI bus enumeration of disks will change depending on cold boot or warm boot. This causes symcli commands to fail
because the path is changed and SYMCLI can no longer communicate with the Symmetrix.
By "shutdown" and booting system, internal disks are assigned first, followed by Symmetrix disks.
By "restart" the system, Symmetrix disks are assigned first, followed by internal disks. Drive letter are not changed in both cases.
The workaround is to perform "symcfg discover" after rebooting.
4. Requires Stratus ftServer OS 1.4.x or greater.
5. Supports Stratus OS 1.2.2.X through 2.1.X.
6. Requires Stratus OS 3.1
7. Supports Stratus OS 4.1 FTSSS Release
8. Supports Stratus OS 1.2.2.X through 1.4.X.
9. Requires PowerPath 3.0.2.
10. Requires Stratus ftServer OS 1.4.x.
Sun

Sun

No. Host System Minimum Host Bios
1 Sun Netra T20001S10 Update 1 (01/06)
2 Sun Sun Blade Server Module X6240, Sun Sun Blade Server Module X6440, Sun Sun Blade Server Module X6450 Refer to Sun support website
3 Sun Sun Fire V20z, Sun Sun Fire V40z 1.26.08 (April 2004)
1. Must add "set sd:sd_io_time=60", "set sd:sd_max_throttle=20", "set ssd:ssd_io_time=60", and "set ssd:ssd_max_throttle=20" in the /etc/system file for Symmetrix or CLARiiON
attach. Do not include quotes on these entries.
Unisys

Unisys

No. Host System Minimum Host Bios
1 Unisys CS720111.0
2 Unisys DR/2, Unisys ES20232, Unisys ES2025 6.00.36
3 Unisys DS/2 6.00.5
4 Unisys ES2024 9
5 Unisys ES2026 A02
6 Unisys ES2026L A03
7 Unisys ES2043215.6 −009
8 Unisys ES20452, Unisys ES5045, Unisys QS/2215.7 −008
9 Unisys ES2046, Unisys ES2046L, Unisys ES3105, Unisys ES3140, Unisys ES3140L A05
10 Unisys ES2085, Unisys ES5085 22.7 Unisys 22.6 ICL_006 ICL
11 Unisys ES3020 A08
12 Unisys ES3020L A15
13 Unisys ES3040, Unisys ES3040L A09
14 Unisys ES3120, Unisys ES3120L, Unisys ES3140, Unisys ES3140L A00
15 Unisys ES3220, Unisys ES3220L 1.1.0, 1.3.6
16 Unisys ES3240L 1.1.4
Host BIOS

03/04/2009 955 Host BIOS