Installing a Summit X480 AC PSU

WARNING!

To prevent an electrical hazard, make sure that the AC power cord is not connected to the PSU before you install the PSU in the power supply bay.

CAUTION

Make sure that the AC PSU circuit is not overloaded. Use proper over-current protection, such as a circuit-breaker, to prevent over-current conditions.

To install a Summit X480 AC PSU:

1Attach an ESD-preventive wrist strap to your bare wrist and connect the metal end to an appropriate grounding point.

2If necessary, remove a blank panel from the back of the Summit X480 series switch (Figure 108).

Figure 108: Removing a Blank Panel

SH_137

3Verify that the PSU is right side up, with the latching tab at the left of the unit (see Figure 106).

4Carefully slide the PSU all the way into the power supply bay (see Figure 106). Push the PSU in until the latch snaps into place.

CAUTION

Do not slam the PSU into the switch.