Table 33: Summit X150 Series Switch Technical Specifications (Continued)

Power consumption (Watts)

Summit X150-48t Power

Operational voltage range Nominal input ratings Input current

Line frequency range

Inrush current

Power supply cord type Power supply input socket Power cord input plug Power cord wall plug Power supply cord gauge

Efficiency

Heat dissipation (BTU) Heat dissipation (Watts) Power consumption (BTU) Power consumption (Watts)

Safety Standards

North American Safety of ITE

European Safety of ITE

International Safety of ITE

EMI/EMC Standards

North America EMC for ITE

European EMC standards

International EMC certifications

500

90 to 264 V

100 to 240 V , 50/60 Hz, 1.0 A

0.6A @ 115 V (low-line)

0.3A @ 230 V (high-line)

47 to 63 Hz

30 A @ 115 V, 60 A @ 230 V

AC

IEC 320 C14

IEC 320 C13

Refer to “Selecting Power Supply Cords” on page 218.

18 AWG (0.75 mm2) up to 6 feet or 2 meters or

16 AWG (1.0 mm2) over 6 feet

83%

170.6

50

170.6

50

UL 60950-1:2003 1st Ed., Listed Device (US) CSA 22.2#60950-1-03 1st Ed.(Canada)

Complies with FCC 21CFR 1040.10 (US Laser Safety) CDRH Letter of Approval (US FDA Approval)

IEEE 802.3af 6-2003 Environment A for PoE Applications

EN 60950-1:2001+A11

EN 60825-1+A2:2001 (Lasers Safety) TUV-R GS Mark by German Notified Body 73/23/EEC Low Voltage Directive

CB Report & Certificate per IEC 60950-1:2001 Country Deviations AS/NZX 60950-1 (Australia /New Zealand)

FCC CFR 47 part 15 Class A (USA)

ICES-003 Class A (Canada)

EN 55022:1998 Class A

EN 55024:1998 Class A includes IEC 61000-4-2, 3, 4, 5, 6, 8, 11 EN 61000-3-2,3 (Harmonics & Flicker)

ETSI EN 300 386:2001 (EMC Telecommunications) 89/336/EEC EMC Directive

CISPR 22:1997 Class A (International Emissions)

CISPR 24:1997 Class A (International Immunity)

IEC/EN 61000-4-2 Electrostatic Discharge, 8kV Contact, 15kV Air, Criteria A

IEC/EN 61000-4-3 Radiated Immunity 10V/m, Criteria A IEC/EN 61000-4-4 Transient Burst, 1kV, Criteria A

IEC/EN 61000-4-5 Surge, 2kV L-L, 2kV L-G, Level 3, Criteria A IEC/EN 61000-4-6 Conducted Immunity, 0.15-80MHz, 10V/m unmod. RMS, Criteria A

IEC/EN 61000-4-11 Power Dips & Interruptions, >30%, 25 periods, Criteria C

Summit Family Switches Hardware Installation Guide

229

 

 

Page 229
Image 229
Extreme Networks 17001 manual Summit X150-48t Power, Safety Standards, EMI/EMC Standards