Installing Summit Family Switches

4Disconnect the ground wire as follows:

a Remove the screw that secures the ground wire to the PSU. b Move the wire away from the PSU.

5Push the latching tab to the left as you pull outward on the handle to disengage the PSU internal connectors (see Figure 142).

Figure 142: Removing a DC PSU

SH_113

Removing a Summit X650 Series Switch from a Two-Post Rack

Removing the Summit X650 switch from a rack requires two people to maneuver the switch and disconnect the mounting hardware.

CAUTION

Make sure that proper ESD controls are in use before maintenance is performed. This includes but is not limited to wrist straps that are grounded to the switch chassis and earth grounds.

To remove the Summit X650 series switch from a two-post rack:

1Attach an ESD-preventive wrist strap to your wrist and connect the metal end to an appropriate ground point on the rack.

2Verify that the power supplies have been removed from the switch.

3At the front of the equipment rack, support the switch while you remove the rack-mounting screws holding the front mounting brackets in place against the rack post (Figure 143).