Extreme Networks 17001 manual 247

Models: 17001

1 274
Download 274 pages 9.67 Kb
Page 247
Image 247

Table 38: Summit X450e Series Switch Technical Specifications (Continued)

Power supply cord type Power supply input socket Power cord input plug Power cord wall plug Power supply cord gauge

Heat dissipation, Watts/BTU Power consumption, Watts/BTU

Safety Standards

North American Safety of ITE

European Safety of ITE

International Safety of ITE

EMI/EMC Standards

North America EMC for ITE

European EMC standards

International EMC certifications

Country-specific

Telecom Standards

IEEE 802.3 Media Access Standards

Environmental Data

Environmental standards

AC

IEC 320 C14

IEC 320 C13

Refer to “Selecting Power Supply Cords” on page 218.

18 AWG (0.75 mm2) up to 6 feet or 2 meters or

16 AWG (1.0 mm2) over 6 feet

180 W/614.2 BTU/hr

603 W/2057.5 BTU/hr

UL 60950-1:2003 1st Ed., Listed Device (US) CSA 22.2#60950-1-03 1st Ed.(Canada)

Complies with FCC 21CFR 1040.10 (US Laser Safety) CDRH Letter of Approval (US FDA Approval)

IEEE 802.3af 6-2003 Environment A for PoE Applications

EN 60950-1:2001+A11

EN 60825-1+A2:2001 (Lasers Safety) TUV-R GS Mark by German Notified Body 73/23/EEC Low Voltage Directive

CB Report & Certificate per IEC 60950-1:2001 Country Deviations AS/NZX 60950-1 (Australia /New Zealand)

FCC CFR 47 part 15 Class A (USA)

ICES-003 Class A (Canada)

EN 55022:1998 Class A

EN 55024:1998 Class A includes IEC 61000-4-2, 3, 4, 5, 6, 8, 11 EN 61000-3-2,3 (Harmonics & Flicker)

ETSI EN 300 386:2001 (EMC Telecommunications) 89/336/EEC EMC Directive

CISPR 22:1997 Class A (International Emissions)

CISPR 24:1997 Class A (International Immunity)

IEC/EN 61000-4-2 Electrostatic Discharge, 8kV Contact, 15kV Air, Criteria A

IEC/EN 61000-4-3 Radiated Immunity 10V/m, Criteria A IEC/EN 61000-4-4 Transient Burst, 1kV, Criteria A

IEC/EN 61000-4-5 Surge, 2kV L-L, 2kV L-G, Level 3, Criteria A IEC/EN 61000-4-6 Conducted Immunity, 0.15-80MHz, 10V/m unmod. RMS, Criteria A

IEC/EN 61000-4-11 Power Dips & Interruptions, >30%, 25 periods, Criteria C

VCCI Class A (Japan Emissions)

AS/NZS 3548 ACA (Australia Emissions)

CNS 13438:1997 Class A (BSMI-Taiwan)

MIC Mark, EMC Approval (South Korea)

ETSI EN 300 386:2001 (EMC Telecommunications)

ETSI EN 300 019 (Environmental for Telecommunications)

IEEE 802.3ab 1000BASE-T

EN/ETSI 300 019-2-1 v2.1.2 - Class 1.2 Storage EN/ETSI 300 019-2-2 v2.1.2 - Class 2.3 Transportation EN/ETSI 300 019-2-3 v2.1.2 - Class 3.1e Operational EN/ETSI 300 753 (1997-10) - Acoustic Noise

ASTM D3580 Random Vibration Unpackaged 1.5G

Summit Family Switches Hardware Installation Guide

247

 

 

Page 247
Image 247
Extreme Networks 17001 manual 247