Installing Summit Family Switches

Figure 135: Attaching Terminals to Cables

Power connection wire

SH_109

Ground wire

SH_110

Installing the Power Supply

CAUTION

The handle on the Summit X650 DC PSU is not designed to be used to lift or carry the Summit X650 series switch.

To install a Summit X650 DC PSU:

1Attach an ESD-preventive wrist strap to your bare wrist and connect the metal end to an appropriate ground point on the rack.

2If necessary, remove a blank panel from the back of the Summit X650 series switch (Figure 136).

Figure 136: Removing a Blank Panel

SH_106

3Verify that the PSU is right side up (see Figure 137).

4Carefully slide the PSU all the way into the power supply bay (see Figure 137). Push the PSU in until the latch snaps into place.

CAUTION

Do not slam the PSU into the switch.

160

Summit Family Switches Hardware Installation Guide

 

 