Extreme Networks 17001 manual Connecting the EPS-160 Power Supply to the Switch

Models: 17001

1 274
Download 274 pages 9.67 Kb
Page 176
Image 176

Installing Summit External Power Supplies

Connecting the EPS-160 Power Supply to the Switch

One end of the EPS-160 redundant power cord has a keyed connector to ensure correct alignment of the connector (Figure 148). The key is a plastic tab on the cord connector housing that fits into the EPS-160 unit to ensure correct alignment of the connector.

Figure 148: Redundant Power Cord Connector

ES4K027

CAUTION

Always connect the redundant power supply cord before you attach the AC power cord to the EPS-160 power supply.

To connect the EPS-160 power supply to the switch:

1Connect the keyed end of the redundant power supply cord to the EPS-160 power supply (see Figure 149).

2Connect the other end of the redundant power supply cord to the Extreme switch (see Figure 149). This connector end can only be inserted into the switch with the end marked TOP facing up.

NOTE

If your switch was shipped with a metal cover plate over the redundant power input connector, remove the cover.

WARNING!

The redundant power input connector on the rear of the switch contains high energy and is a burn hazard. Use care when connecting the redundant power supply cord to the rear of the switch.

Figure 149: Redundant Power Connections

Slot for plug

To AC

Keyed end of

redundant power cable

Redundant power cable

S450_008

176

Summit Family Switches Hardware Installation Guide

 

 

Page 176
Image 176
Extreme Networks 17001 manual Connecting the EPS-160 Power Supply to the Switch, Redundant Power Connections