NOTE

Kinks and sharp bends can destroy or impair the cable’s ability to convey light pulses accurately from one end of the cable to the other. Use care in dressing the optical fiber cables: provide satisfactory strain relief to support the cable and maintain an adequate bend radius at all cable turns, particularly where the cable connects to the I/O module.

Figure 67: Bend Radius for Fiber Optic Cable

Minimum

2-in. (5.08-cm)

radius

in 90∞ bend

90∞

Optical fiber cable

SPG_002

Cable Distances

Table 18 shows cable media types and maximum distances that support reliable transmission in accordance with international standards except where noted.

Table 18: Media Types and Maximum Distances

Standard

Media Type

Mhz•Km

Maximum Distance

Rating

(Meters)

 

 

 

 

1000BASE-SX

50/125 μm multimode fiber

400

500

(850 nm optical

50/125 μm multimode fiber

500

550

window)

62.5/125 μm multimode fiber

160

220

 

 

62.5/125 μm multimode fiber

200

275

1000BASE-LX

50/125 μm multimode fiber

400

550

(1300 nm optical

50/125 μm multimode fiber

500

550

window)

62.5/125 μm multimode fiber

500

550

 

 

10/125 μm single-mode fiber

5,000

 

10/125 μm single-mode fiber*

10,000

1000BASE-LX70

10/125 μm single-mode fiber

70,000

(1550 nm optical

 

 

 

window)

 

 

 

1000BASE-T

Category 5 and higher UTP cable

100

100BASE-TX

Category 5 and higher UTP cable

100

10BASE-T

Category 3 and higher UTP cable

100

 

 

 

 

*Proprietary to Extreme Networks. Connections between two Extreme Networks 1000BASE-LX interfaces that use 10/125 μm single-mode fiber can use a maximum distance of 10,000 meters.

Summit Family Switches Hardware Installation Guide