Extreme Networks 17001 manual Dual 600-LS Module Configuration Full Power

Models: 17001

1 274
Download 274 pages 9.67 Kb
Page 78
Image 78

Summit Power Supplies

Dual 600-LS Module Configuration: Full Power

Two EPS-600LS power modules provide full power at 740 W, which allows 15.4 W of PoE power to all 48 ports. In this full-power configuration, the internal power supply is disabled, and therefore redundant power is not available.

Triple 600-LS Module Configuration: Full Redundant Power

Three EPS-600LS power modules provide the full 740 W of power for 15.4 W of PoE power to all 48 ports. In addition, this configuration provides 2:1 redundancy. Should one of the EPS-600LS power modules fail, the third power module continues to provide uninterrupted full PoE power. The internal power supply is disabled in this configuration.

Internal-to-External PSU Transfer

This section describes the conditions that would cause the Summit X450e-48p or X250e-48p switch to draw power from the external power unit.

Internal PSU Failure with Single EPS-600LS Module. When an EPS-C with a single EPS-600LS is connected to the Summit X450e-48p or X250e-48p switch and the internal PSU fails, power is drawn from the EPS- 600LS without power interruption to the PoE connected devices.

Two or Three EPS-600LS Modules. When the Summit X450e-48p or X250e-48p switch detects that an EPS- C is connected and providing stable power from two or three EPS-600LS power modules, the PoE power budget is automatically recalculated to enable 740 W of PoE power. The internal PSU is disabled to prevent damage from excessive current demands beyond the internal PSU's capabilities.

External-to-Internal PSU Transfer

This section describes the conditions where power from an external power module either fails or is disconnected.

Active Internal PSU with Single 600-LS Module Failure. When an EPS-C configured with a single EPS- 600LS module is connected to the Summit X450e-48p or X250e-48p switch and the EPS-600LS fails or is disconnected, power is drawn from the internal PSU without power interruption to the PoE connected devices.

Inactive Internal PSU with a Dual EPS-600LS Configuration and Module Failure. This section describes the PoE behavior when an EPS-C chassis configured with two EPS-600LS modules is connected to the Summit X450e-48p or X250e-48p switch and one or both EPS-600LS modules fail or are disconnected.

It is possible for one external power module to fail while the second power module continues to function. If one EPS-600LS fails, the PoE power budget is automatically reduced to 370 W for the Summit X450e-48p or X250e-48p switch. PoE port power management occurs as described in the Power over Ethernet section of the Extre me XOS Conce pts Guide . With only a single operating power module, the remaining EPS-600LS behaves as a redundant power module. The internal PSU is returned to an active state to provide redundant capability.

If both external power modules fail or are disconnected, PoE power is interrupted while transferring PoE power back to the internal PSU. The internal PSU is then limited to 370 W of PoE power. The PoE power budget is automatically adjusted accordingly. Power management will occur as described in the Power over Ethernet section of the Extre me XOS Conce pts Guide .

78

Summit Family Switches Hardware Installation Guide

 

 

Page 78
Image 78
Extreme Networks 17001 manual Dual 600-LS Module Configuration Full Power, Internal-to-External PSU Transfer