Table 39: Summit X480 Series Switch Technical Specifications (Continued)

Power consumption, Watts, BTU 148 W, 503 BTU/hr

Summit X480-48t with VIM2-SummitStack Module (DC Power Supply)

Nominal input ratings

48 V

 

, 7.0 A

 

 

 

 

 

 

 

Input current

3.24

A @ 48 V

 

 

(low-line)

 

 

 

2.5 A @ 60 V

 

 

 

(high-line)

 

 

 

 

Heat dissipation, Watts, BTU

153 W, 520 BTU/hr

Power consumption, Watts, BTU

153 W, 520 BTU/hr

Summit X480-48t with VIM2-10G4X Module (DC Power Supply)

Nominal input ratings

48 V

 

, 7.0 A

 

 

 

Input current

3.1 A @ 48 V

 

(low-line)

 

 

2.4 A @ 60 V

 

(high-line)

 

 

Heat dissipation, Watts, BTU

148 W, 503 BTU/hr

Power consumption, Watts, BTU

148 W, 503 BTU/hr

 

 

 

 

 

 

Safety Standards

 

 

 

 

 

North American Safety of ITE

UL 60950-1 1st Ed., Listed Device (US)

 

CSA 22.2 #60950-1-03 1st Ed.(Canada)

 

Complies with FCC 21CFR 1040.10 (US Laser Safety)

 

CDRH Letter of Approval (US FDA Approval)

European Safety of ITE

EN 60950-1:2006

 

EN 60825-1+A2:2001 (Lasers Safety)

 

TUV-R GS Mark by German Notified Body

 

2006/95/EC Low Voltage Directive

International Safety of ITE

CB Report & Certificate per IEC 60950-1:2006 + National Differences

 

AS/NZX 60950-1 (Australia /New Zealand)

EMI/EMC Standards

 

 

 

 

 

North America EMC for ITE

FCC CFR 47 part 15 Class A (USA)

 

ICES-003 Class A (Canada)

European EMC standards

EN 55022:2006 Class A

 

EN 55024:A2-2003 Class A includes IEC 61000-4-2, 3, 4, 5, 6, 11

 

EN 61000-3-2,8-2006 (Harmonics)

 

EN 61000-3-3 1995+A2:2005 (Flicker)

 

ETSI EN 300 386 v1.3.3, 2005-04 (EMC Telecommunications)

 

2004/108/EC EMC Directive

International EMC certifications

CISPR 22: 2006 Ed 5.2, Class A (International Emissions)

 

CISPR 24:A2:2003 Class A (International Immunity)

EC/EN 61000-4-2:2001 Electrostatic Discharge, 8kV Contact, 15 kV Air, Criteria A

EC/EN 61000-4-3:2006 Radiated Immunity 10V/m, Criteria EC/EN 61000-4-4:2005 Transient Burst, 1 kV, Criteria A

IEC/EN 61000-4-5:2005 Surge, 2 kV L-L, 2 kV L-G, Level 3, Criteria A IEC/EN 61000-4-6:2005 Conducted Immunity, 0.15-80 MHz, 10V/m unmod. RMS, Criteria A

EC/EN 61000-4-11:2004 Power Dips & Interruptions, >30%, 25 periods, Criteria C

Country-specific

Telecom Standards

IEEE 802.3 Media Access Standards

VCCI Class A (Japan Emissions)

ACMA (C-Tick) (Australia Emissions)

CCC Mark

KCC Mark, EMC Approval (Korea)

ETSI EN 300 386:2001 (EMC Telecommunications)

ETSI EN 300 019 (Environmental for Telecommunications)

IEEE 802.3ab 1000BASE-T