The rear panel of the Summit X250e-48tDC switch (Figure 18) includes:

Management port with associated LEDs

Two high-performance stacking ports with associated LEDs

Redundant power input connector for use with the EPS-150DC External Power Module (Model No. 10909).

See “EPS-150DC External Power Module (with EPS-T2)” on page 76 for more information. The connecting redundant power supply cable is shipped with the EPS-150DC unit.

DC power input socket.

The power supply operates from -36 VDC to -72 VDC.

Grounding lug

NOTE

For centralized DC power connection, this product is intended to be installed in a restricted access location (such as a dedicated equipment room, equipment closet, or central office) in accordance with Articles 110-16, 110-17, and 110-18 of the National Electric Code, ANSI/NFPA 70.

Figure 20: Summit X250e-48tDC Switch Rear Panel

 

External power

Management port

supply connection

Redundant Power Input

-48 V

2.0 A Max

! See Manual

10 Gigabit

DC power

stacking ports

socket

SH_063_rear_x250e-48tdc

Summit Family Switches Hardware Installation Guide