Extreme Networks 17001 manual Connecting the EPS-150DC to a Switch

Models: 17001

1 274
Download 274 pages 9.67 Kb
Page 187
Image 187

Figure 158: Connecting the Input Cable to the EPS-150DC Unit

EPS-150DC

in EPS-T2

DC wiring harness

EPS-15DC_001C

3Tighten the retainer nut on the connector until it is finger tight.

Connecting the EPS-150DC to a Switch

If you are connecting the EPS-150DC unit to a Summit X450a-48tDC switch, you must ground the switch before connecting power. For instructions on grounding the switch, see “Grounding a Summit DC-Powered Switch” on page 123.

WARNING!

Always be sure that the DC circuit is de-energized before connecting the EPS-150DC to the switch.

One end of the EPS-150DC cord has a keyed connector to ensure correct alignment of the connector (Figure 159). The key is a plastic tab on the connector housing that fits into the EPS-150DC unit to ensure correct alignment of the connector.

Figure 159: EPS-150DC Redundant Power Cord with Connector Key

Collin's

ES4K027

XM_055

To connect the EPS-150DC to a switch:

1Verify that the DC power is turned off at the source.

2Identify the keyed end of the redundant power cable.

3Holding the keyed connector so that the side labeled “Top” is facing up, connect the EPS-150DC redundant power cable to the power supply unit (see Figure 160).

4Align and tighten the connector retaining screws to secure the cable connector to the power supply unit.

5Connect the other end of the redundant power cord to the Extreme switch. The connector fits the slot in only one direction.

6Align and tighten the captive retaining screws to secure the cable connector to the switch.

Summit Family Switches Hardware Installation Guide

187

 

 

Page 187
Image 187
Extreme Networks 17001 manual Connecting the EPS-150DC to a Switch, Connecting the Input Cable to the EPS-150DC Unit