Replacing a Versatile Interface Module (VIM)

The procedure for replacing a VIM is the same for both the VIM1 module in the Summit X650 series switch and the VIM2 module in the Summit X480 series switch.

NOTE

VIM1 modules must be installed in Summit X650 series switches, and VIM2 modules must be installed in Summit X480 switches. A VIM1 or VIM2 module will not operate if it is installed in the wrong switch series.

You need the following tools and materials to replace a VIM1 or VIM2 module:

ESD-preventive wrist strap

#2 Phillips screwdriver

CAUTION

Summit VIM1 and VIM2 modules are not hot-swappable. Disconnect power to the switch before removing an installed VIM1 or VIM2 module. After a VIM1 or VIM2 module is installed in a compatible switch, you can hot-swap SFP and SFP+ modules. Use only SFP and SFP+ modules approved by Extreme Networks.

To replace a VIM1 or VIM2 module:

1Attach an ESD-preventive wrist strap to your wrist and connect the metal end to an appropriate ground point on the rack.

2Disconnect the switch power.

3Remove the installed VIM (Figure 180):

a Remove the retaining screws at the top corners of the module, and set the screws aside in a safe place.

Save the retaining screws to secure the new module in the switch.

b Rotate the inserter/extractor levers downward to disconnect the internal module connectors. c Carefully slide the module out of the switch and set it on an anti-static surface.

Figure 180: Removing a VIM (VIM1-SummitStack Module Shown)

SH_092

4Remove the replacement VIM from its anti-static packaging.