Extreme Networks 17001 manual Installing External Power Supply Units

Models: 17001

1 274
Download 274 pages 9.67 Kb
Page 216
Image 216

Safety Information

Installing External Power Supply Units

For the ratings and power requirements of each power supply unit, see Appendix B, “Technical Specifications” or the data sheet for the power supply at http://www.extremenetworks.com.

WARNING!

Be sure that the requirements listed in this section are satisfied when installing all Extreme Networks power supplies.

When you install external power supplies:

Plug power supplies only into properly grounded electrical outlets to help prevent electrical shock and comply with international safety standards.

Use only power cords that are certified for use within the country of use. Do not attempt to modify AC power cords.

Make sure the wall outlet is installed near the equipment and is easily accessible for quick disconnect.

Make sure the voltage and frequency of your power outlet match the system electrical ratings for the equipment. The building and/or power source must provide overload protection.

Use a surge suppressor, line conditioner, or uninterruptible power supply to protect the system from momentary increases or decreases in electrical power.

When inserting a power supply into the bay, do not use excessive force.

If multiple power supplies are used with a switch, connect each power supply to a different, independent power source. If a single power source fails, it will affect only that power supply to which it is connected. If all the power supplies on a single switch are connected to the same power source, the entire switch is vulnerable to a power failure.

WARNING!

Wiring a DC power cord to your facility DC source voltage must be performed by a qualified, licensed electrician.

Extreme Networks AC external power supplies do not have switches for turning the unit on and off. Remove the wall plug from the electrical outlet to disconnect the power from an Extreme Networks AC external power supply. Make sure that this connection is easily accessible.

Do not connect an EPS-600LS power supply to an electrical outlet when the power supply is not installed in the EPS-C chassis; doing so would expose a hazardous energy and poses a potential shock and fire hazard.

Do not put your hand into an open power supply bay when a power supply is not present. Empty power supply bays require a cover plate at all times.

216

Summit Family Switches Hardware Installation Guide

 

 

Page 216
Image 216
Extreme Networks 17001 manual Installing External Power Supply Units