cRepeat steps a and b for the other side of the EPS-C.

4Slide the EPS-C into a 19-inch rack and secure it using appropriate rack-mount screws.

5Connect the keyed end of the redundant power cord to the EPS-C (see Figure 163). Verify that the side of the connector marked TOP is facing up.

The key is a plastic tab on the cable connector housing that fits into the EPS-C to ensure correct alignment of the connector.

6Connect the other end of the redundant power cord to the Summit X450e-48p or X250e-48p switch (see Figure 163). Be sure that the side of the connector marked TOP is facing up.

Figure 163: Installing the Redundant Power Cord

Connect First

Redundant Power Output

! See Manual

EPS-C_03A

Installing an EPS-600LS Power Supply

To install an EPS-600LS unit into an EPS-C:

1If necessary, remove a cover plate from a slot in the EPS-C.

2Slide the EPS-600LS into an empty slot in the EPS-C (see Figure 164).

CAUTION

Be sure that empty slots in the EPS-C chassis are always covered by a cover plate when not in use. The EPS-C is shipped with slots 2 and 3 covered and slot 1 open. Extreme Networks recommends that you populate slot 1 with an EPS-600LS unit first, but this is not required. You can install EPS-600LS units into any of the slots in the EPS-C. The installation sequence does not affect the performance of the power supply units, but empty slots must be covered at all times.

Summit Family Switches Hardware Installation Guide

191

 

 

Page 191
Image 191
Extreme Networks 17001 manual Installing an EPS-600LS Power Supply, Installing the Redundant Power Cord