Extreme Networks 17001 Installing an EPS-600LS Power Supply, Installing the Redundant Power Cord

Models: 17001

1 274
Download 274 pages 9.67 Kb
Page 191
Image 191

cRepeat steps a and b for the other side of the EPS-C.

4Slide the EPS-C into a 19-inch rack and secure it using appropriate rack-mount screws.

5Connect the keyed end of the redundant power cord to the EPS-C (see Figure 163). Verify that the side of the connector marked TOP is facing up.

The key is a plastic tab on the cable connector housing that fits into the EPS-C to ensure correct alignment of the connector.

6Connect the other end of the redundant power cord to the Summit X450e-48p or X250e-48p switch (see Figure 163). Be sure that the side of the connector marked TOP is facing up.

Figure 163: Installing the Redundant Power Cord

Connect First

Redundant Power Output

! See Manual

EPS-C_03A

Installing an EPS-600LS Power Supply

To install an EPS-600LS unit into an EPS-C:

1If necessary, remove a cover plate from a slot in the EPS-C.

2Slide the EPS-600LS into an empty slot in the EPS-C (see Figure 164).

CAUTION

Be sure that empty slots in the EPS-C chassis are always covered by a cover plate when not in use. The EPS-C is shipped with slots 2 and 3 covered and slot 1 open. Extreme Networks recommends that you populate slot 1 with an EPS-600LS unit first, but this is not required. You can install EPS-600LS units into any of the slots in the EPS-C. The installation sequence does not affect the performance of the power supply units, but empty slots must be covered at all times.