S e c t i o n F i v e

POWER ON SELF TEST MESSAGES

The following is an alphabetic list of error-and- status messages which Phoenix BIOS and/or your operating system can generate and an explanation of each message.Error messages are marked with an *. Comments in italics

are suggestions of possible actions for you to consider or risks resulting from ignoring the message. The most common errors are marked with a #. If an error message is displayed that is not in this list, write it down and check your operating system documentation both on screen and in the manual. If you can find no reference to the message and its meaning is not clear, contact your support representative

for assistance.

nnnnCache SRAM Passed – Where nnnn is the amount of system cache in kilobytes successfully tested by the Power On Self Test (POST). (This can only appear if you have an SRAM PC Card installed.)

*Diskette drive A error or Diskette drive B error – Drive A: or B:is present but fails the

BIOS Power On Self Test (POST) diskette tests. Check to see that the drive is defined with the proper diskette type in the Utility Setup, (see page 59,) and that the diskette drive is installed cor- rectly, (see pages 121 and 122). If the disk drive is properly defined and installed avoid using it and contact your support representative.

*Extended RAM Failed at offset:nnnn – Extended memory not working or not config- ured properly. If you have an installed a memor y upgrade module verify that the module is proper- ly installed. If it is properly installed you may want to check your Windows Setup so it is not trying to use unavailable memory until you can contact your support representative.

nnnnExtended RAM Passed – Where nnnn is the amount of memory in kilobytes successfully tested.

*Failing Bits:nnnn – The hex number nnnn is a map of the bits at the memory address (in System, Extended, or Shadow memory) which failed the memory test. Each 1 (one) in

the map indicates a failed bit. This is a serious fault which might cause you to lose data if you continue. Contact your support representative.

*Fixed Disk x Failure or Fixed Disk Controller Failure (where x = 1-4) – Fixed disk is not working or not configured properly. This may mean that the hard drive type identified in your Setup Utility does not agree with the type detected by the Power On Self Test (POST). Run the Setup Utility to check for the hard disk type settings and correct them if necessary. If the settings are OK and the message appears when you restart the system there may be a serious fault which might cause you to lose data if you continue. Contact your support representative.

*Incorrect Drive A type – run SETUP – Type of floppy drive A: not correctly identified in Setup. This means that the floppy disk drive type identified in your Setup Utility does not agree with the type detected by the Power On Self Test (POST). Run the Setup Utility to correct the inconsistency.