DMC-1400 Series Command Reference SB 181
SB
FUNCTION: Set Bit
DESCRIPTION:
The SB command sets one of three bits on the output port.
Note: When using Modbus devices (DMC-1415/1416/1425 ONLY), the I/O points of the
Modbus devices are calculated using the following formula:
n = (SlaveAddress*10000) + (HandleNum*1000) + ((Module-1)*4) + (Bitnum-1)
Slave Address is used when the Modbus device has slave devices connected to it and specified
as Addresses 0 to 255. Please note that the use of slave devices for Modbus are very rare and
this number will usually be 0.
HandleNum is the handle specifier from A to F.
Module is the position of the module in the rack from 1 to 16.
BitNum is the I/O point in the module from 1 to 4.
ARGUMENTS: SB n where
n is an integer in the range 1 to 3 decimal.
USAGE:
While Moving Yes Default Value ---
In a Program Yes Default Format ---
Command Line Yes
Can be Interrogated No
Used as an Operand No
Controller Usage ALL
RELATED COMMAND:
OP Configure output port
CB Clear Bit
EXAMPLES:
SB 3 Set output line 3
SB 1 Set output line 1