192 TC DMC-1400 Series Command Reference
ECAM
28 S operand not valid 105 EB1 command must be given first
29 Not valid during coordinated move 110 No hall effect sensors detected
30 Sequence segment too short 111 Must be made brushless by BA
command
31 Total move distance in a sequence > 2
billion
112 BZ command timeout
32 More than 511 segments in a sequence 113 No movement in BZ command
33 VP or CR commands cannot be mixed
with LI commands
114 BZ command runaway
41 Contouring record range error 118 Controller has GL1600 not GL1800
42 Contour data being sent too slowly 120 Bad Ethernet transmit
46 Gear axis both master and follower 121 Bad Ethernet packet received
50 Not enough fields 122 Ethernet input buffer overrun
51 Question mark not valid 123 TCP lost sync
52 Missing " or string too long 124 Ethernet handle already in use
53 Error in {} 125 No ARP response from IP address
54 Question mark part of string 126 Closed Ethernet handle
55 Missing [ or [] 127 Illegal Modbus function code
56 Array index invalid or out of range 128 IP Address not valid
57 Bad function or array 130 Illegal IOC Command
58 Not a valid Command Operand
(i.e._GNX)
131 Serial Port Handshake timeout
59 Mismatched parentheses
USAGE:
While Moving Yes Default Value ---
In a Program Yes Default Format 3.0
Command Line Yes
Can be Interrogated Yes
Used as an Operand Yes
Controller Usage ALL
OPERAND USAGE: _TC contains the value of the error code. EXAMPLES:
:GF32 Bad command
?TC Tell error code
1 Unrecognized command