DMC-1400 Series Command Reference BC 35
BC
FUNCTION: Brushless Calibration
DESCRIPTION:
The function BC monitors the status of the Hall sensors of a sinusoidally commutated motor,
and upon transition, replaces the estimated value of a commutated phase by an exact
value.
ARGUMENTS: BC
USAGE:
While Moving Yes Default Value 0
In a Program Yes Default Format 0
Command Line Yes
Can be Interrogated No
Used as an Operand Yes
Controller Usage DMC-1412/1415/1410/1417
OPERAND USAGE:
_BC contains the state of the Hall sensor inputs. This value should be between 1 and 6.
RELATED COMMANDS:
BA Brushless Axis
BB Brushless Phase Begins
BD Brushless Degrees