30 #AUTO DMC-1400 Series Command Reference
#AUTO
FUNCTION: Subroutine to run automatically upon power up
DESCRIPTION:
#AUTO denotes code to run automatically when power is applied to the controller, or after
the controller is reset. When no host software is used with the controller, #AUTO and the
BP command are required to run an application program on the controller.
USAGE:
While Moving Yes
In a Program Yes
Command Line No
Controller Usage ALL
RELATED COMMANDS:
BP Burn program
EXAMPLES:
#AUTO ;'move the x axis upon power up
PRX=1000 ;'move 1000 counts
BGX ;'begin motion
AMX ;'wait until motion is complete
EN
NOTE: Use EN to end the routine