DMC-1400 Series Command Reference TI ● 197
TI FUNCTION: Tell Inputs
DESCRIPTION:
This command returns the state of all 7 general digital inputs or 3 inputs for the DMC-1425.
Response is a decimal number which when converted to binary represents the status of all
7 digital inputs.
BIT TI
Bit 6 Input 7
Bit 5 Input 6
Bit 4 Input 5
Bit 3 Input 4
Bit 2 Input 3
Bit 1 Input 2
Bit 0 Input 1
ARGUMENTS: TI
USAGE:
While Moving Yes Default Value ---
In a Program Yes Default Format 3.0
Command Line Yes
Can be Interrogated Yes
Used as an Operand Yes
Controller Usage ALL
OPERAND USAGE:
_TI contains the status byte of the input block. Note that the operand can be masked to return
only specified bit information - see section on Bitwise operations
EXAMPLES:
TI
08 Input 4 is high, others low
TI
00 All inputs low
Input =_TI Sets the variable, Input, with the TI value
TI