Comparing State Traces

Set Up the State Trigger Specification

Set Up the State Trigger Specification

When comparing two state listings, it is best to only sample the data you are interested in comparing. This will ensure that the errors you find are errors in the data you are interested in, rather than in the pretrigger data. Setting the analyzer to store "no state" before the trigger, tells the analyzer to begin capturing data after the trigger is found.

1If the Trigger Menu is not already displayed, press the Trigger MENU key.

2Highlight the 1 field in the State Sequence Levels box, and press the

Select key.

3Highlight the field to the right of While storing, and press the Select key. Highlight no state in the pop-up menu, and press the Select key.

4Highlight the field to the right of Trigger on, and press the Select key. Highlight a in the pop-up menu, and press the Select key. Press the Done key to close the Sequence Level 1 pop-up menu.

5Highlight the 2 field in the State Sequence Levels box, and press the

Select key.

6Highlight the field to the right of Store, and press the Select key. Highlight anystate in the pop-up menu, and press the Select key. Press the Done key to close the Sequence Level 2 pop-up menu.

Result

The trigger specification is now:

 

Level 1 -

While storing "no state", trigger on "a" 1 time

 

Level 2 -

Store "any state"

4-5