Mixed Mode - Correlation of State and Timing Data

View the Mixed-Mode Display with Time-Correlated Markers

View the Mixed-Mode Display with Time-Correlated Markers

When you press the Run key, the state analyzer triggers on the pattern FF (when all eight lines are high) and arms the timing trigger. Mixed Display displays trigger points for both the timing analyzer and the state analyzer with the state data displayed in a state listing and the timing data displayed in a timing waveform.

1Press the Run key.

2Press the List MENU key. Choose Mixed Display from the pop-up menu.

Notice the delay between the state trigger and the timing trigger, causing the timing trigger marker to appear to the right of the FF state. This is due to the time required for the state analyzer to arm the timing analyzer.

3Highlight the Trig to X field and rotate the knob to observe that the X markers move in both the state listing and the timing waveform displays.

The state analyzer trigger point (FF).

The X-marker.

The timing analyzer trigger point to the right of the FF state.

The X-marker.

The delay between the state trigger and the timing trigger. The FF state is where all eight lines are high.

Mixed Mode Display

4Press the Trigger MENU key twice.

5Highlight the Count Time Off in the pop-up menu,

field, and press the Select key twice. Highlight and press the Select key. Press the Done key.

Steps 4 and 5 turn off the Time Count function for the next exercise.

5-10