Training Guide
Training Kit for HP 1660/70 Series Logic Analyzers
Easy Steps to Logic Analysis with the HP 1660/70 Series
Ready, Set, Run
Next
Logic Analysis made easy a self-paced training guide
Using a Mouse
This Book
Contents
Mixed Mode Correlation of State and Timing Data
Triggering the Oscilloscope with the Timing Analyzer
Setting the Jumpers and Loading the Configurations
Using the Analyzer Understanding Measurement Process
Using the Analyzer and Understanding the Measurement Process
To Highlight a Field
Using the Analyzer
To Select a Field
To Scroll Through Lists and Menus
Map to target
Understanding the Measurement Process
Set up analyzers
Configure Arming Control Use Arming Control if
Set up trigger
Run Measurement
View data
Introduction to Timing Analysis
Introduction to Timing Analysis
Decide what to do next
Before You Begin
Connect Pod
Set the jumpers as shown below
Analyzer is Timing mode
Put the Analyzer into Timing Mode
Press the Done key
Change a Label Name
Modify Channel Assignments
Define a Term for the Timing Trigger
Set Up the Trigger Specification
Do This
Trigger on the Term and Examine the Waveform
Page
Introduction to State Analysis
Introduction to State Analysis
Introduction to State Analysis
Analyzer is in state mode
Put the Analyzer into State Mode
Press the Done key to close the Master Clock pop-up menu
Set Up the State Clock
Represents state count
Modify the Channel Assignments
Press the Trigger Menu key
Define a Term for the State Trigger
Continuing until the trigger pattern 00 is found
Set Up Level 1 of the State Trigger Specification
Press the Done key to close the Sequence Level 2 pop-up menu
Set Up Level 2 of the State Trigger Specification
Use the table below to view and change the state listing
Press the Run key Observe the State Listing
When the base field is set to Symbol
Create Symbols to Display State Data
Create Additional Symbols
Press the List Menu key
Select and View Symbols in the State Listing
Comparing State Traces
Comparing State Traces
Load the Analyzer with the configuration file, CH04.A
Check the configuration
Check the Configuration
Set Up the State Trigger Specification
Press the Run key Observe the listing
Run the Analyzer and View the State Listing
Reference listing
Copy the State Listing to the Compare Reference
Change the Jumper to Acquire a Different State Listing
Run the Analyzer and Find the Errors
Page
Mixed Mode Correlation of State and Timing Data
Mixed Mode Correlation of State and Timing Data
Load the Analyzer with the configuration file, CH05.A
Connect the Timing Analyzer
Connect the Pod 3 connector to the probe assembly
+5 V power for the training board
Put the Analyzer into State and Timing Modes
Press the Config Menu key
Turn on the Tcount Label in the Waveform Menu
Change a Label Name and Modify Channel Assignments
Press the Waveform Menu key to display Waveform Machine2
A3 assigned to it
Clear the Timing Analyzer Trigger
Enable Time Correlation between the Timing State Analyzers
Press the Done key to return to the Trigger Menu
Arm the Timing Analyzer with the State Analyzer
Press the Trigger Menu key twice
View the Mixed-Mode Display with Time-Correlated Markers
Advanced State Triggering
Advanced State Triggering
Load the Analyzer with the configuration file, CH06.A
Channel of pod A1 are showing activity
022, 033,
Define State Trigger Terms a through d
Assigned decimal values 050 through
Define State Trigger Term e and Range1
Add State Trigger Sequence Levels
Set Up Level 1 of the State Trigger Specification
Then find and store the term e value
Press the Done key to close the Sequence Level 3 pop-up menu
Set Up Level 3 of the State Trigger Specification
Defining a Combination Trigger Term
Before finding and triggering on term e
Press the Done key to close the Sequence Level 4 pop-up menu
Check the Trigger Specification
Term e, followed by anystate
Run the State Analyzer and View the Data
Ripple Counter Output and Stored States
Page
Using the Oscilloscope
Using the Oscilloscope
Load the configuration files CH07.A and CH07.B
Connect the Channel 1 Oscilloscope Probe
Supply the +5 V power for the training board
Channel C1
Get the Waveform on the Display
Occupies the entire display
Delete Channel 2 from the Display
Highlight the s/Div field
Zoom and Scroll Through the Clock Waveform
Read the period of the clock in the Tx to To field
Measure the Clock Period Manually
Read the clock period in the box below the top row of fields
Measure the Clock Period with Auto Measure
Read Voltage with the Markers
Triggering the Oscilloscope with the Timing Analyzer
Triggering the Oscilloscope with the Timing Analyzer
Load the configuration files CH08.A, and CH08.B
Set the Jumpers
If Pod 1 is not connected to J1, connect it now
Connect the Oscilloscope Probe
Running the Oscilloscope with Autoscale
Glitch
Change the Oscilloscope Trigger
Turn On the Timing Analyzer
Set to glitch
Set Up the Timing Format Menu
Press the Format Menu key
Define the Timing Trigger Term Edge
Set Up the Timing Trigger Specification
Which allows the scope to capture the glitch
Arm the Oscilloscope with the Timing Analyzer
Press the Done key to exit the Arming Control pop-up menu
Add Oscilloscope Waveform to the Timing Waveforms
Displayed when you run the analyzer
Capture the Glitch with the Timing Analyzer Oscilloscope
Align the Glitch Displayed by the Oscilloscope Analyzer
Analyzer display is time-aligned with the scope display
Using the Pattern Generator
Using the Pattern Generator
Load the configuration file for , CH0360.A
Pod 4 of the pattern generator
Connect the Pattern Generator
Turn On the Timing Analyzer
Highlight Turn Label Off, and press the Select key
Modifying the Channel Assignments
Set Up the Timing Analyzer Trigger Term
Add a Pattern Generator Label to the Timing Waveform Display
Set Up the Pattern Generator Format Menu
Lower four bits of Pod 4 is assigned to the label Patgen
Use the knob to scroll to the field under
Program the Pattern Generator Output
0001, 0010, 0100, 1000 to the logic analyzer
Add Program Lines
Using the Pattern Generator
Stop the Pattern Generator
Page
Introduction to Inverse Assembly
Introduction to Inverse Assembly
Load the Inverse Assembler and Sample Listing
Necessary configurations
View the Address, Data, and Status Labels
View the Assembly Listing
HP 1661C, or the HP 1661CS analyzer
Filter the Captured Data
Setting the Jumpers and Loading the Configurations
Setting the Jumpers
To Set the Jumpers
Loading the Configurations
To Load a Configuration File
Select key. Choose Analyzer in the pop-up menu
Highlight the Execute field, then press the Select key
All About the Logic Analyzer Training Board
Circuit Description
Power Source
Jumpers
Jumpers
Schematic
Index
Errors
Index
Document Warranty
Product Warranty