Advanced State Triggering

Set Up Level 1 of the State Trigger Specification

Set Up Level 1 of the State Trigger Specification

The first term you will look for and store before triggering is term "a", which stores the value 011. Because you are only interested in 011, you will set the "While Storing" field to "no state" so that no other data is stored.

1Highlight the 1 field in the State Sequence Levels box of the Trigger menu. Press the Select key.

2In the pop-up menu, highlight the field to the right of While storing, and press the Select key. Highlight no state in the pop-up menu, and press the Select key.

3Highlight the field to the right of Find, and press the Select key. Highlight a in the pop-up menu, and press the Select key.

4Press the Done key to close the Sequence Level 1 pop-up menu.

The analyzer will not store any data before it finds term "a".

The "a" term holds the decimal value

 

Setting Up Level 1 of the State Trigger Specification

Result

Sequence Level 1 is set to find and store only term "a" the first time it occurs.

6-8