Table 10 Fault Symptom Codes (continued)

 

 

 

 

 

FSC

Message

ERP

2010

Ctl. Firmware Error

•

Cycle power to the library or reboot

 

(Internal task processing error.

 

using the GUI touch screen.

 

•

Upgrade firmware if a newer revision

 

Unexpected event. SMX send or receive

 

error.)

 

exists.

 

 

 

 

2030

Drive Timeout Error

•

Check if the drive shows good status

 

 

 

through the drive status window.

 

 

• Cycle power to the library or reboot

 

 

 

using the GUI touch screen.

 

 

•

Reseat drive.

 

 

 

 

2080

Drive Code Update Command Error

•

Make sure that the firmware is the correct

 

(Update code from SCSI or from tape

 

file for this product.

 

•

Check if the drive shows good status

 

failed.)

 

 

 

through the drive status window.

 

 

• Cycle power to the library or reboot

 

 

 

using the GUI touch screen.

 

 

• Attempt firmware upgrade again.

 

 

 

 

2081

Move Command Failure

•

Press the Enter button to reboot.

 

(Move command from or to drive slot

•

Ensure the drive shows good status

 

failed. Detected by control task.)

 

through the drive status window.

 

 

• Cycle power to the library or reboot

 

 

 

using the GUI touch screen.

 

 

• Load/unload a cartridge to the drive to

 

 

 

verify.

 

 

 

 

2090

Open Mail Slot Fault

•

Press the Enter button to clear the

 

(Door open sensor time-out detected

 

message.

 

•

Cycle power to the library or reboot

 

when open door.)

 

 

 

using the GUI touch screen.

 

 

•

Run sensor test.

 

 

• Make sure door(s) are closed.

 

 

 

 

2091

Open Left Door Fault

•

Press the Enter button to clear the

 

(Door open sensor time-out detected

 

message.

 

•

Cycle power to the library or reboot

 

when open door.)

 

 

 

using the GUI touch screen.

 

 

•

Run sensor test.

 

 

• Make sure door(s) are closed.

 

 

 

 

MSL6000 series tape library user guide 107