Table 6 View SCSI Options

Option

Description

Drive 0 Bus ID

Lets you set the SCSI addresses of drive 0. The designators

 

Drive 0 (outer tape drive) through Drive n refer to the first

 

through nth drives, counting from right to left starting with

 

the master unit in a scaled Library system. Default is 1.

 

 

Drive 1 Bus ID

Lets you set the SCSI addresses of drive 1. The designators

 

Drive 1 (inner tape drive) through Drive n refer to the

 

second through nth drives, counting from right to left

 

starting with the master unit in a scaled Library system.

 

Default is 2.

 

 

Drive 2 Bus ID

Lets you set the SCSI addresses of drive 2. The designators

(four-drive models

Drive 2 (lower, outer tape drive) through Drive n refer to

only)

the third through nth drives, counting from right to left

 

starting with the master unit in a scaled Library system.

 

Default is 3.

 

 

Drive 3 Bus ID

Lets you set the SCSI addresses of drive 3. The designators

(four-drive models

Drive 3 (lower, inner tape drive) through Drive n refer to

only)

the fourth through nth drives, counting from right to left

 

starting with the master unit in a scaled Library system.

 

Default is 4.

 

 

Library SCSI Bus ID

Lets you set the SCSI addresses for the library robotics. The

 

default is 0.

 

 

Library SCSI Bus Parity

Lets you enable or disable the library robotics SCSI bus

 

parity checking. The default is Enabled.

 

 

Mail Slot Access

This option controls access to the mail slot and media

 

removal. “Prevent Allow” Command Inhibits allows access

 

to the mail slot via the GUI control panel and allows

 

media removal. “Prevent Allow” Command Ignored

 

prevents access to the mail slot and removal of media. This

 

option is used for some backup applications. The default is

 

“Prevent Allow” Command Inhibits.

 

 

SCSI Mode

Defines the loader as SCSI-2or SCSI-3. The default is

 

SCSI-3.

 

 

Unit Attention

Lets you select reporting of all or only one stacked-unit

Reporting

attention conditions. If set to Report All, the unit reports all

 

unit attention conditions in sequence; if set to Report One,

 

the unit reports only the highest priority condition. The

 

default is Report All.

 

 

64 Operation

Page 64
Image 64
HP MSL6000 manual SCSI-3