Table 10 Fault Symptom Codes (continued)

 

 

 

 

FSC

Message

ERP

9003

Master pass-thru opto failed.

• Press the Enter button to reboot.

 

(The master module opto sensor was not

• Run the sensor test, checking appropriate

 

detected during the power-up

sensor.

 

Pass-Through module inventory.)

• Determine if the pass-through may have

 

 

been plugged or unplugged while power

 

 

was on to the library.

 

 

• Reinitialize or power-cycle the master it is

 

 

connected to. Ensure the pass-through is

 

 

functioning by observing whether or not

 

 

the pass-through car moves to either end

 

 

of the pass-through smoothly.

 

 

 

A001

SMX send error

• Press the Enter button to reboot.

 

(An attempt to place a message on a

• Cycle power to the library or reboot

 

task’s exchange generated a kernel

using the GUI touch screen.

 

error.)

 

 

 

 

A002

SMX receive error

• Press the Enter button to reboot.

 

(An attempt to receive a message from a

• Cycle power to the library or reboot

 

task’s exchange generated a kernel

using the GUI touch screen.

 

error.)

 

 

 

 

A003

Comm free list empty

• Press the Enter button to reboot.

 

(An attempt to acquire a message from

• Cycle power to the library or reboot

 

the free pool failed because the pool is

using the GUI touch screen.

 

empty.)

 

 

 

 

A004

Invalid comm. put attempt

• Press the Enter button to reboot.

 

(An attempt to place a message on a

• Cycle power to the library or reboot

 

task’s exchange failed.)

using the GUI touch screen.

 

 

 

A005

Invalid comm. get attempt

• Press the Enter button to reboot.

 

(An attempt to receive a message from a

• Cycle power to the library or reboot

 

task’s exchange failed.)

using the GUI touch screen.

 

 

 

A006

Comm initialization error

• Press the Enter button to reboot.

 

(The Comm manager could not be

• Cycle power to the library or reboot

 

initialized at power-up because system is

using the GUI touch screen.

 

out of memory.)

 

 

 

 

A007

Put of a NULL comm.

• Press the Enter button to reboot.

 

 

• Cycle power to the library or reboot

 

 

using the GUI touch screen.

 

 

 

MSL6000 series tape library user guide 133

Page 133
Image 133
HP MSL6000 manual Fsc