Table 10 Fault Symptom Codes (continued)

 

 

 

 

 

FSC

Message

ERP

307A

Diag get drive 2 status failed

•

Press the Enter button to reboot.

 

(Failed to get drive status, communication

•

Ensure the drive shows good status

 

error.)

 

through the drive status window.

 

 

• Deactivate the drive using the GUI control

 

 

 

panel maintenance menu.

 

 

•

Reseat drive.

 

 

•

Check cabling.

 

 

• Load/unload a cartridge to the drive to

 

 

 

verify.

 

 

• Check the tape cartridge used in the last

 

 

 

operation for damage.

 

 

• Run the cartridge cycle diagnostic to

 

 

 

verify.

 

 

 

 

307B

Diag get drive 3 status failed

•

Press the Enter button to reboot.

 

(Failed to get drive status, communication

•

Ensure the drive shows good status

 

error.)

 

through the drive status window.

 

 

• Deactivate the drive using the GUI control

 

 

 

panel maintenance menu.

 

 

•

Reseat drive.

 

 

•

Check cabling.

 

 

• Load/unload a cartridge to the drive to

 

 

 

verify.

 

 

• Check the tape cartridge used in the last

 

 

 

operation for damage.

 

 

• Run the cartridge cycle diagnostic to

 

 

 

verify.

 

 

 

 

3082

Drive Stow Failed, Media Returned to

•

Press the Enter button to clear the

 

Source

 

message.

 

 

• Use only media approved for the drive

 

 

 

type.

 

 

• Invalid user initiated operation. Set

 

 

 

parameters correctly and try again.

 

 

 

 

3083

Drive Stow Failed, Media Remains in

•

Press the Enter button to clear the

 

Drive

 

message.

 

 

• Invalid user initiated operation. Set

 

 

 

parameters correctly and try again.

 

 

• Ensure cartridges are in magazines.

 

 

 

 