Table 12 Library Diagnostic Tests

 

 

 

Test

Description

Cartridge Cycle

Cycles cartridges continuously and

 

randomly in bins and mail slots,

 

displaying a count of the type of cycle

 

on the control panel. Press the Start

 

button to begin the test and the Stop

 

button end to end the test.

 

 

Drive Cycle

Cycles cartridges continuously and

 

randomly in bins, mail slots, and

 

drives, displaying a count of the type of

 

cycle on the control panel. Press the

 

Start button to begin the test and the

 

Stop button end to end the test.

 

 

Barcode Cycle

Scans all bar codes continuously,

 

listing those read and the number of

 

times a full library scan has been done.

 

Press the Start button to begin the test

 

and the Stop button end to end the

 

test.

 

 

Inventory

Physically scans the entire library to

 

determine which slots and drives

 

contain tapes and reads all barcode

 

labels.

 

 

Sensor Test

Tests all the hall effect sensors and lists

 

their status.

 

 

Vertical Calibration

Calibrates the vertical lifters to correct

(available in four-drive models only)

limits. This test is typically used when

 

vertical lifters are replaced.

 

 

View Error Log

Allows access to the error log to view

 

posted errors.

 

 

Touch Screen Calibrate

Allows resetting of calibration values

 

when the screen brightness is not

 

uniform.

 

 

Tachometer Diagnostic

This is a factory only diagnostic used to

 

measure tachometer motor function

 

limits.

 

 

Friction Diagnostic

This is a factory only diagnostic used to

 

measure friction in the motors for

 

acceptable limits.

 

 

142 Troubleshooting

Page 142
Image 142
HP MSL6000 manual Their status