Table 10 Fault Symptom Codes (continued)

 

 

 

 

 

FSC

Message

ERP

3075

Drive 1 Eject Failed

Press the Enter button to reboot.

 

(Eject command time-out.)

Ensure the drive shows good status

 

 

 

through the drive status window.

 

 

Deactivate the drive using the GUI control

 

 

 

panel maintenance menu.

 

 

Reseat drive.

 

 

Load/unload a cartridge to the drive to

 

 

 

verify.

 

 

Check the tape cartridge used in the last

 

 

 

operation for damage.

 

 

Run the cartridge cycle diagnostic to

 

 

 

verify.

 

 

 

 

3076

Drive 2 Eject Failed

Press the Enter button to reboot.

 

(Eject command time-out.)

Ensure the drive shows good status

 

 

 

through the drive status window.

 

 

Deactivate the drive using the GUI control

 

 

 

panel maintenance menu.

 

 

Reseat drive.

 

 

Load/unload a cartridge to the drive to

 

 

 

verify.

 

 

Check the tape cartridge used in the last

 

 

 

operation for damage.

 

 

Run the cartridge cycle diagnostic to

 

 

 

verify.

 

 

 

 

3077

Drive 3 Eject Fail

Press the Enter button to reboot.

 

(Eject command time-out.)

Ensure the drive shows good status

 

 

 

through the drive status window.

 

 

Deactivate the drive using the GUI control

 

 

 

panel maintenance menu.

 

 

Reseat drive.

 

 

Load/unload a cartridge to the drive to

 

 

 

verify.

 

 

Check the tape cartridge used in the last

 

 

 

operation for damage.

 

 

Run the cartridge cycle diagnostic to

 

 

 

verify.

 

 

 

 