Table 10 Fault Symptom Codes (continued)

 

 

 

 

FSC

Message

ERP

8002

Drive Fan stalled

Press the Enter button to clear the

 

(The fan in the drive hot-swap shoe is

message.

 

Look for a drive with an amber LED (rear

 

either not installed or has stalled.)

 

 

of library) to determine which drive has

 

 

the fan issue. If the drive is not in use,

 

 

take it off-line to prevent it from

 

 

overheating. If currently in use, end the

 

 

operation immediately, and take the drive

 

 

off-line.

 

 

 

8003

Drive load did not complete

Press the Enter button to reboot.

 

(The drive failed to successfully load a

Ensure the drive shows good status

 

tape.)

through the drive status window.

 

 

Cycle power to the library or reboot

 

 

using the GUI touch screen.

 

 

Check the tape cartridge used in the last

 

 

operation for damage.

 

 

 

8004

Invalid drive was installed

Press the Enter button to clear the

 

(One or more installed drives are of a

message.

 

Update the firmware if a newer revision

 

type either unknown or not supported in

 

the current library personality.)

exists.

 

 

Invalid user initiated operation. Set

 

 

parameters correctly and try again.

 

 

 

9001

Orphan cartridge recovery failed

Make sure there is one empty slot in a

 

(The master module could not successfully

magazine in the master module.

 

Press the Enter button to reboot.

 

return an orphan cartridge to a slot

 

location.)

Cycle power to the library or reboot

 

 

using the GUI touch screen.

 

 

Check pass-through alignment.

 

 

Ensure that there are no obstructions

 

 

inside the library (all cartridges are in

 

 

magazines).

 

 

Check the tape cartridge used in the last

 

 

operation for damage.

 

 

 

132 Troubleshooting

Page 132
Image 132
HP MSL6000 manual Magazine in the master module