Table 10 Fault Symptom Codes (continued)

 

 

 

 

 

FSC

Message

ERP

305B

Diag Fetch, Drive not loaded

Press the Enter button to clear the

 

(Diag: no cartridge present for fetch.)

 

message.

 

Load a cartridge in the drive and retry

 

 

 

 

 

the operation.

 

 

Invalid user initiated operation. Set

 

 

 

parameters correctly and try again.

 

 

 

 

305D

Diag Timeout waiting for drive empty,

Press the Enter button to reboot.

 

ready

Invalid user initiated operation. Set

 

(Fetch, time-out waiting for drive unload.)

 

parameters correctly and try again.

 

 

Ensure the drive shows good status

 

 

 

through the drive status window.

 

 

Check the tape cartridge used in the last

 

 

 

operation for damage.

 

 

 

 

305F

Invalid bin number

Press the Enter button to clear the

 

(Invalid bin number detected in diag.)

 

message.

 

Invalid user initiated operation. Set

 

 

 

 

 

parameters correctly and try again.

 

 

 

 

3060

Zone Sequence Error

Cycle power to the library or reboot

 

(Robot did not find sensor on power-up.)

 

using the GUI touch screen.

 

 

 

 

 

 

 

3074

Drive 0 Eject Failed

Press the Enter button to reboot.

 

(Eject command time-out.)

Ensure the drive shows good status

 

 

 

through the drive status window.

 

 

Deactivate the drive using the GUI control

 

 

 

panel maintenance menu.

 

 

Reseat drive.

 

 

Load/unload a cartridge to the drive to

 

 

 

verify.

 

 

Check the tape cartridge used in the last

 

 

 

operation for damage.

 

 

Run the cartridge cycle diagnostic to

 

 

 

verify.

 

 

 

 

116 Troubleshooting