4 Switch Interface Administration

Digital Interfaces

Table 12. Parameter Values for Assign Card: Digital R2 MFC - Mexico Window

Field Name

Value

 

 

Framing/Line Coding:

CEPTHDB3

 

 

Idle Code:

01010100

 

 

DTMF Muting:

Yes

 

 

A-LAW or MU-LAW:

A-LAW

 

 

CRC:

Yes

 

 

Max. Digits in Called Number:

4

 

 

Outgoing Addressing Type:

MFC

 

 

Incoming Addressing Type:

MFC

 

 

Incoming Speech Volume:

1414

 

 

Outgoing Speech Volume:1

707

1 This field is displayed only if the optional SSP Text-to-Speech package is installed. This field applies only to SSP Text-to-Speech output volume. The LSPS output volume cannot be changed.

4Press F3 (Save).

The system saves the parameter information and assigns the Digital R2 MFC - Mexico protocol to the selected E1 circuit card.

UCS 1000 R4.2 Administration 585-313-507