A Summary of Commands

diagnose card

offline tests and a conflict is detected, the user is asked whether to wait until the conflict is resolved or to terminate the request to diagnose.

If a unit fails the diagnostics, the permanent state is changed to BROKEN. If the unit being diagnosed previously was marked BROKEN and it passes diagnostics, it is put in the MANOOS state. Otherwise, the permanent state is unchanged.

When diagnostics are complete, if the diagnostics passed, the T1/E1, SSP, and LSPS cards are reinitialized.

If an SSP card passes diagnostics, the system displays a message similar to the following:

Diagnose <card> n, Passed.

If a T1 card passes diagnostics, the system displays a message similar to the following:

All tests passed.

If a T1 card fails diagnostics, a help screen is provided giving you information to help resolve the reason for the failure. If you try to diagnose cards that are not installed in the system or if they are installed but are in the nonexistent state, the system displays an error message.

To delete out of the command, press D EL . If this does not stop the command, you may need to press C TR L and backslash simultaneously. Be aware, however, that this fixes the console, but does not terminate the

UCS 1000 R4.2 Administration 585-313-507

Issue 3 April 2000 429