IBM H80 Series manual Additional Communication Attributes, 11/31/41 51/61 Settings Attributes

Models: H80 Series

1 230
Download 230 pages 61.65 Kb
Page 116
Image 116

Additional Communication Attributes

The following communication attributes apply to the 3151, 3161, and 3164 terminals.

Communication

 

3151

3151

3161/3164

Description

 

 

 

 

 

 

 

 

 

 

 

 

Setup

 

 

/11/31/41

/51/61

Settings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Attributes

 

Settings

Settings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operating

mode

Echo

Echo

Echo

Data

entered

from

the

keyboard

on

 

 

 

 

 

 

the

 

terminal

is

sent

to

the

system

 

 

 

 

 

 

unit

 

for

 

translation

and

then

sent

 

 

 

 

 

 

 

back to the display screen.

 

 

 

 

 

 

 

Sometimes

calledconversational

 

 

 

 

 

 

 

 

 

 

mode .

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Line

speed

9600

9600

9600

Uses

the

 

9600

bps

(bits

per

 

 

 

 

bps

bps

bps

second)

line

speed

to

 

 

 

 

 

 

 

 

 

 

 

communicate

 

with

the

system

unit.

 

 

 

 

 

 

 

 

 

 

 

 

 

Word

length

8

8

8

Selects

eight

bits

as

a

data word

(bits)

 

 

 

 

length (byte).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parity

 

No

No

No

Does

not

add

a

parity

bit, and

is

 

 

 

 

 

 

used together with the word length

 

 

 

 

 

 

attribute

to

form

the

8-bit

data

 

 

 

 

 

 

word

(byte).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stop

bit

 

1

1

1

Places a bit after a data word

 

 

 

 

 

 

(byte).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Turnaround

 

CR

CR

CR

Selects

the

carriage

return

(CR)

 

character

 

 

 

character as the line turnaround

 

 

 

 

 

 

 

character.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Interface

EIA-232

EIA-232

EIA-232

Uses

the

 

EIA-232

interface

 

 

 

 

 

 

 

 

protocol.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Line

control

IPRTS

IPRTS

IPRTS

Uses

the

 

Permanent

Request

to

 

 

 

 

 

 

 

Send

 

(IPRTS)

signal

to

 

 

 

 

 

 

 

 

 

 

 

 

communicate

 

with

system

unit.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Break

signal

500

500

500

The

terminal

sends

a

Break

 

Signal

 

(ms)

 

 

 

 

 

to

the

system

unit

within

500

ms

 

 

 

 

 

 

 

after the Break key is pressed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Send

null

suppress

On

On

 

Trailing

null

characters

are

not

 

 

 

 

 

 

 

sent

 

to

the system

unit.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Send

null

 

 

 

On

Trailing

null

characters

are

sent

to

 

 

 

 

 

 

the

 

system

unit.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Response

delay (ms)100

100

100

The

terminal

waits

for

100ms

for

 

 

 

 

 

 

 

the

 

system

unit

to

respond.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100 RS/6000 Enterprise Server Model H80 Series User's Guide