Download Microcode to Disk Drive Attached to a PCI SCSI RAID

Adapter

See the following command syntax for a disk drive attached to a PCI SCSI RAID Adapter.

diag -c -d RAID adapterName-T "download {-l chID -A} [-D] [-P]"

Flag

Description

 

 

-A

All disk

drives

-D

Microcode is

on diskette /etc/microcode(default to directory)

-l

RAID disk drive–physical disk channel/ID (example 27)

-P

Download

the

previous level of microcode (default to latest level)

Download

Microcode to a

PCI FC-AL Adapter

See

the following

command syntax for a PCI FC-AL Adapter.

diag -c -d device_name-T "download [-s {diskettedisk}] [-f] [-l {latestprevious}]"

Flag

Description

 

 

 

-d

Device name is the name

of

the

adapter.

-f

Force the download even

if

the

current level of microcode is not on the

 

media.

 

 

 

-l

Level

of microcode

to

download. The default is latest.

-s

Source of the new microcode. The default value is disk.

The

microcode

image file

must

be/etc/microcodelocated in.

Download Microcode

to

Other

Devices

 

 

The

following

usage

statements describe the syntax

of the command:

diag -c -d device_name-T "download [-s diskette] [-l previous] [-F]"

Flag

Description

 

 

 

 

 

-F

Force flag. Required to download microcode if the current level is

 

unavailable

on

the

source.

 

-l

Microcode level. Latest is default.

 

-s

Source

of

the

new

microcode. The /etc/microcodedefault

is. Default

 

source

device

is

disk.

 

Chapter 6. Introducing Tasks and Service129 Aids

Page 145
Image 145
IBM H80 Series manual PCI FC-AL Adapter, Microcode to a, Be/etc/microcodelocated, Devices