The service aid transmitted a SCSI Inquiry Command and an adapter error
occurred.
The service aid transmitted a SCSI Inquiry Command and a check condition
occur.
When the SCSI Bus Service Aid is started, a description of the service aid displays.
Pressing the Enter key displays the Adapter Selection menu. Use this menu to enter
the address to transmit the SCSI Inquiry Command.
When the adapter is selected the SCSI Bus Address Selection menu displays. Use
this menu to enter the address to transmit the SCSI Inquiry Command.
After the address is selected, the SCSI Bus Test Run menu displays. Use this
menus to transmit the SCSI Inquiry Command by pressing Enter. The service aid
then indicates the status of the transmission. When the transmission is completed,
the results of the transmission displays.
Notes:
A Check Condition can be returned when the bus or device is working
correctly.
AIX does not allow the command to be sent if the device is in use by another
process.
SCSD Tape Drive Service Aid
This service aid allows you to obtain the status or maintenance information from a
SCSD tape drive. Not all models of SCSI tape drive are supported.
The service aid provides the following options:
Display time since a tape drive was last cleaned.
The time since the drive was last cleaned displays on the screen, as well as a
message regarding whether the drive is recommended to be cleaned.
Copy a tape drive's trace table.
The trace table of the tape drive is written to diskettes or a file. The diskettes
must be formatted for DOS. Writing the trace table may require several diskettes.
The actual number of diskettes is determined by the size of the trace table.
Label the diskettes as follows:
TRACE[
x
].DAT