Enable

supplemental

restart

policy

 

- The default setting is NO. If set to

YES,

the

service

processor

restarts the system when the system loses

control as

detected

by service

processor surveillance, and either:

 

The Use

OS-Defined restart

policy

is

set to NO.

 

OR

 

 

 

 

 

 

The Use OS-Defined restart policy is set to YES, and the operating system has NO automatic restart policy.

Refer to “Service Processor Reboot/Restart Recovery” on page 64.

Call-Out before

restart

(Enabled/Disabled)

- If a restart is

necessary

due

to

a system

fault,

you

can enable

the

service processor

to

call

out

and report

the event. This option can be valuable if the number

of

these

events

becomes

excessive,

signalling a

bigger

problem.

 

 

 

 

Ÿ Power-On System

Allows immediate power-on of the system. For other power-on methods, see “Powering On the System” on page 4.

ŸPower-Off System

Allows the user to power-off the system.

ŸEnable/Disable Fast System Boot

Allows the user to select the IPL type, mode, and speed of your boot capabilities

Attention:

Selecting the

fast

IPL

results in several diagnostic tests being skipped

and a

shorter memory

test

being

run.

42 RS/6000 Enterprise Server Model H80 Series User's Guide

Page 58
Image 58