Modem Configuration Sample FilesSample File modem_m0.cfg
#
# COMPONENT_NAME: (ESPSETUP) ENTRY SERVICE PROCESSOR SETUP: modem_mð
#
# FUNCTIONS: Modem configuration file specifically for IBM 7852-4ðð
# modem with Auto-Reliable feature. This feature must be turned off
# for Catcher calls. This example uses the AT&F reset command to
# choose the factory defaults.
#
# (C) COPYRIGHT International Business Machines Corp. 1996
# All Rights Reserved
# Licensed Materials - Property of IBM
#
# US Government Users Restricted Rights - Use, duplication or
# disclosure restricted by GSA ADP Schedule Contract with IBM Corp.
#
#
# The modem has configuration switches. They should be set to the
# factory default settings, except switches 11 and 12. These must be
# to UP ("AT" responses) and DOWN (Asynchronous operation), respectively.
ICDelay 1
DefaultTO 1ð
CallDelay 12ð
#
# %N Call-Out phone number %R Return phone number
#
#
# PROGRAMMING NOTE: No blanks between double quote marks (").
condout: send "AT&F&E2EðT\r" # Reset to factory defaults
# Reliable mode
# Echo off
ignore "ð\r" or "OK\r\n" timeout 2 # Ignore modem response.
send "AT&E12&E14\r" # Disable pacing
# Disable data compression
expect "ð\r" or "OK\r\n" timeout 2 # Confirm commands successful.
send "AT&SF1&SðS9=1\r" # DSR independent of CD
# Force DSR on.
# CD respond time=1ððms
expect "ð\r" or "OK\r\n" timeout 2 # Confirm commands successful.
send "ATVðSð=ð\r" # Numeric response code
# Auto-Answer off
expect "ð\r" or "OK\r\n" timeout 2 # Confirm commands successful.
done
connect: send "ATDT%N\r" # Tone dialing command.
# %N from Call Home setup.
186 RS/6000 Enterprise Server Model H80 Series User's Guide