8XC196MC, MD, MH USER’S MANUAL

COMPx_CON

COMPx_CON (Continued)

Address:

Table C-3

x = 0–3 (8XC196MC, MH)

Reset State:

 

x = 0–5 (8XC196MD)

 

 

The EPA compare control (COMPx_CON) registers determine the function of the EPA compare channels.

x = 0, 2, 4

x = 1, 3, 5

7

TB

CE

M1

M0

7

 

 

 

 

 

 

 

TB

CE

M1

M0

 

 

 

 

0

RE

WGR

ROT

RT

 

 

 

0

 

 

 

 

RE

AD

ROT

RT

 

 

 

 

2

WGR

A/D Conversion, Waveform Generator Reload

 

AD

The function of this bit depends on the EPA channel.

 

 

 

 

For EPA capture/compare channels 0, 2, 4:

 

 

The WGR bit allows you to use the EPA activities to cause the reload of

 

 

new values in the waveform generator.

 

 

0 = no action

 

 

1 = enables waveform generator reload

 

 

For EPA capture/compare channels 1, 3, 5:

 

 

The AD bit allows you to use the EPA activities to start an A/D

 

 

conversion that has been previously set up in the A/D control registers.

 

 

0 = causes no A/D action

 

 

1 = starts an A/D conversion on an output compare

 

 

 

1

ROT

Reset Opposite Timer

 

 

Selects the timer that is to be reset if the RT bit is set.

 

 

0 = selects the reference timer for possible reset

 

 

1 = selects the opposite timer for possible reset

 

 

The state of the TB bit determines which timer is the reference timer and

 

 

which timer is the opposite timer.

 

 

 

0

RT

Reset Timer

 

 

This bit controls whether the timer selected by the ROT bit will be reset.

 

 

1 = resets the timer selected by the ROT bit

 

 

0 = disables the reset function

 

 

 

C-16

Page 493
Image 493
Intel 8XC196MH, 8XC196MD, 8XC196MC manual For EPA capture/compare channels 0, 2