8XC196MC, MD, MH USER’S MANUAL

PWMx_CONTROL

PWMx_CONTROL

Address:

1FB0H, 1FB2H

x = 0–1

Reset State:

00H

The PWM control (PWMx_CONTROL) register determines the duty cycle of the PWM x channel. A zero loaded into this register causes the PWM to output a low continuously (0% duty cycle). An FFH in this register causes the PWM to have its maximum duty cycle (99.6% duty cycle).

7

0

 

PWM Duty Cycle

 

 

Bit

Function

Number

 

 

 

7:0

PWM Duty Cycle

 

This register controls the PWM duty cycle. A zero loaded into this register causes the

 

PWM to output a low continuously (0% duty cycle). An FFH in this register causes the

 

PWM to have its maximum duty cycle (99.6% duty cycle).

 

 