Thermal Management Specifications

Table 5-19. 4-Core 130W Thermal Profile Table 2U (Sheet 2 of 2)

Power (W)

Maximum TCASE (°C)

Maximum DTS (°C)

 

 

 

85

64.9

80.0

 

 

 

90

65.8

81.7

 

 

 

95

66.7

83.5

 

 

 

100

67.6

85.3

 

 

 

105

68.5

87.1

 

 

 

110

69.4

88.9

 

 

 

115

70.3

90.6

 

 

 

120

71.2

92.4

 

 

 

125

72.1

94.2

 

 

 

130

73.0

96.0

 

 

 

5.1.3.104-Core 130W 1S WS Thermal Specifications

Table 5-20. Tcase: 4-Core 130W 1S WS Thermal Specifications, Workstation/Server Platform

Core

Thermal Design

Minimum

Maximum

Notes

Frequency

Power (W)

TCASE (°C)

TCASE (°C)

 

Launch to FMB

130

5

See Figure 5-21and Table 5-21

1, 2, 3, 4, 5

 

 

 

 

 

Notes:

1.These values are specified at VCC_MAX for all processor frequencies. Systems must be designed to ensure the processor is not to be subjected to any static VCC and ICC combination wherein VCC exceeds VCC_MAX at specified ICC. Please refer to the electrical loadline specifications in Section 7.8.1.

2.Thermal Design Power (TDP) should be used for processor thermal solution design targets. TDP is not the maximum power that the processor can dissipate. TDP is measured at maximum TCASE.

3.These specifications are based on final silicon characterization.

4.Power specifications are defined at all VIDs found in Table 7-3. The processor may be delivered under multiple VIDs for each frequency.

5.FMB, or Flexible Motherboard, guidelines provide a design target for meeting all planned processor frequency requirements.