| 7000 Series L3 Managed Switch Reference Manual for Software v2.0 |
|
|
Serial Port Login | Specifies the time, in minutes, of inactivity on a Serial port con- |
Timeout (minutes) | |
| nection, after which the Switch will close the connection. Any |
| numeric value between 0 and 160 is allowed, the factory default |
| is 5. A value of 0 disables the timeout. |
Baud Rate | The default baud rate at which the serial port will try to connect. |
| This is selected from a |
| 1200, 2400, 4800, 9600, 19200, 38400,57600, and 115200 baud. |
| The factory Default is 9600 baud. |
Character Size | The number of bits in a character. The number of bits is always 8. |
Flow Control | Whether Hardware |
| ware Flow Control is always disabled. |
Stop Bits | The number of Stop bits per character. The number of Stop bits is |
| always 1. |
Parity Type | The Parity Method used on the Serial Port. The Parity Method is |
| always None. |
config serial baudrate
This command specifies the communication rate of the terminal interface. The supported rates are 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200.
Default | 9600 |
Format | config serial baudrate <speed> |
config serial timeout
This command specifies the maximum connect time (in minutes) without console activity. A value of 0 indicates that a console can be connected indefinitely. The time range is 0 to 160.
Default | 5 |
Format | config serial timeout <0 - 160> |
config snmpcommunity accessmode
This command restricts access to switch information. The access mode can be
Format | config | snmpcommunity accessmode <rorw> |
| <name> |
|
|
|
|
Switching Commands |
|