Omron NT31 NT31C manual Using the NT Link 11 Method Compatible Host Units, CVM1-CPU21-EV2

Models: NT31 NT31C

1 296
Download 296 pages 47.55 Kb
Page 122
Image 122

Connecting to the Host’s RS-422A/485 Port

 

 

 

Section 5-2

 

 

 

 

 

 

 

 

 

Allocation DM

 

 

 

 

 

 

 

area (CH)

 

Writing Value

 

Settings

 

Port 2

 

 

 

 

 

 

 

 

 

 

 

 

DM32010

 

8000

Host link mode, 2 stop bits, data length 7 bits,

 

 

 

 

even parity,

 

 

 

 

 

 

 

 

 

 

DM32011

 

0000

Communication speed

9600 bps.

 

 

 

 

 

 

 

 

 

0007

Communication speed

19200 bps.

 

 

 

 

 

 

 

DM32012

 

0000

Transmit delay time

0 ms.

 

 

 

 

 

 

 

DM32016

 

0000

No CTS control

Unit No.0 for host link

Using the NT Link (1:1) Method

Compatible Host Units

Some models and series of OMRON PCs have the RS-422A type NT link (1:1) function built in.

The C200HX/HG/HE(-Z)E CPUs can be connected by the RS-422A type NT link (1:1) method by installing a Communications Board.

The CQM1H CPUs can be connected by the RS-422A type NT link (1:1) meth- od by installing a Serial Communications Board.

Check the model and series of the PC against the type of CPU before making the connections.

The host units that can be connected to the RS-422A port of the NT31/NT31C by the RS-422A type NT link (1:1) method are indicated in the table below.

PC Series

CPUs with Built-in RS-422A type NT

Model Name

Link (1:1) Function

 

 

 

 

 

 

 

 

 

C200HE-CPU32-(Z)E(*1)

C200HE (-Z)E

 

 

C200HE-CPU42-(Z)E(*1)

 

 

 

 

 

C200HG-CPU33-(Z)E(*1)

 

 

 

C200HG-CPU43-(Z)E(*1)

C200HG (-Z)E

 

 

C200HG-CPU53-(Z)E(*1)

 

 

 

 

 

C200HG-CPU63-(Z)E(*1)

 

C series

C200HX-CPU34-(Z)E(*1)

 

 

 

C200HX-CPU44-(Z)E(*1)

 

 

 

C200HX-CPU54-(Z)E(*1)

C200HX (-Z)E

 

 

C200HX-CPU64-(Z)E(*1)

 

 

 

 

 

C200HX-CPU65-ZE(*1)

 

 

 

C200HX-CPU85-ZE(*1)

 

 

 

CQM1H-CPU51/61

CQM1H

 

 

 

 

CV series

CV500-CPU01-EV1

CV500

 

 

CV1000-CPU01-EV1

CV1000

(*22)

 

 

 

 

 

 

CV2000-CPU01-EV1

CV2000

 

 

 

 

CVM1

CVM1-CPU01-EV2

 

CVM1-CPU11-EV2

CVM1

series (*2)

CVM1-CPU21-EV2

 

 

 

 

 

 

 

 

*1

One of the following communication boards is required:

 

C200HW-COM03-EV1 or C200HW-COM06-EV1.

 

*1

A CQM1H-SCB41 Serial Communication Board is required.

*1

CPUs of CVM1/CV series PCs without the suffix -EVjcannot be connected.

The NT link (1:1) method cannot be used using RS-485. To use the NT link (1:1) method, connect by RS-422A.

NT link connection using RS-422A/485 is not possible with CPM1.

Settings at the Host

The setting methods for each type of unit are described in the following.

111

Page 122
Image 122
Omron NT31 NT31C Using the NT Link 11 Method Compatible Host Units, CVM1 CVM1-CPU01-EV2 CVM1-CPU11-EV2, CVM1-CPU21-EV2