Omron NT31 NT31C manual Relationship between System Program Hardware

Models: NT31 NT31C

1 296
Download 296 pages 47.55 Kb
Page 279
Image 279

Appendix I

Relationship between System Program and

Hardware

Here, relationship between system program and hardware is described.

NT31/NT31C have following models.

NT31-ST121j-E

Conventional product

 

 

NT31C-ST141j-E

 

 

 

NT31-ST121j-EV1

Version upgrade model of the products above

 

(12/98)

NT31C-ST141j-EV1

 

 

 

NT31-ST121j-EV2

Version upgrade model of the products above

 

(12/99)

NT31C-ST141j-EV2

 

System programs indicated below are installed for the models shown above in the default state. Also, system pro- grams are supplied with the Support Tool as follows.

System programs for NT31-ST121j-E/NT31C-ST141j-E: System Program Ver. 1.0j (System programs supplied with NT-ZJ3AT1-EV2/ZJCAT1-EV2)

System programs for NT31-ST121j-EV1/NT31C-ST141j-EV1: System Program Ver. 2.0j or 2.1j (System programs supplied with NT-ZJ3AT1-EV3/ZJCAT1-EV3)

System programs for NT31-ST121j-EV2/NT31C-ST141j-EV2: System Program Ver. 3.0j (System programs supplied with NT-ZJCAT1-EV4)

(A system program for the earlier NT30/620 PTs is also included with the NT-ZJCAT1-EV4.)

These system programs have mutual compatibility, therefore, they can be installed and used for NT31-ST121j-E/ NT31C-ST141j-E/NT31-ST121j-EV1/NT31C-ST141j-EV1/NT31-ST121j-EV2/NT31C-ST141j-EV2 each.

However, there will be a limitation on function depending on the combination. Refer to the following table.

Limitations of System Program/PT Combinations

The following table shows only the relationship between the hardware and system program.

For details of the relationship with the screen data created using the Support Tool, refer to NT-series Support Tool for Windows (Ver. 4.1) Operation Manual (V061-E1-j).

Combining a -V1 Version and Version without a -VjSuffix

 

 

Hardware

 

 

 

 

 

 

 

NT31-ST121j-E

 

NT31-ST121j-EV1

 

 

NT31C-ST141j-E

 

NT31C-ST141j-EV1

 

 

 

System program Ver. 1.0j

The following functions cannot be used

The following functions cannot be used

 

S

Analogue meter

S

Analogue meter

 

S

High-definition font display

S

High-definition font display

 

S Installation of system programs using memory unit

S Connection to Mitsubishi PLCs

 

S Connection to Mitsubishi PLCs

S

Memory link

 

S

Memory link

S Window control from the host

 

S Window control from the host

S Multiple display of window screens

 

S Multiple display of window screens

S

Moving a window

 

S

Moving a window

S Refer to the following table for details on new

 

S Refer to the following table for details on new

 

functions supported by the -V2 versions.

 

* Installation of system programs using memory unit

 

 

functions supported by the -V2 versions.

 

 

 

 

is possible

 

 

 

System program Ver. 2.0j or Ver. 2.1j

The following functions cannot be used

The new functions supported by the -V2 versions

 

S Installation of system programs using memory unit

cannot be used. Refer to the following table for details.

 

 

 

SHigh-definition font display

SRefer to the following table for details on new functions supported by the -V2 versions.

*The system program’s version can be checked from the System Menu.

275

Page 279
Image 279
Omron NT31 NT31C manual Relationship between System Program Hardware, Limitations of System Program/PT Combinations