Device Monitor Function

Section 6-13

 

 

 

CN111 or CS1W-CN114/118 Connecting Cable, a CPM1-CIF01 RS-232C

 

 

Adapter, or a CPM1-CIF11 RS-422A Adapter.

 

 

Refer to Section 4 Connecting to the Host from the RS-232C Port or Section 5

 

 

Connecting to the Host from the RS-422A/485 Port for details on connecting to

 

 

the PC.

CS1G/CS1H

The 1:N NT Link (standard or high-speed) can be used. The connection method

 

 

is exactly the same as for the 1:N NT Link.

 

 

Refer to Section 4 Connecting to the Host from the RS-232C Port or Section 5

 

 

Connecting to the Host from the RS-422A/485 Port for details on connecting to

 

 

the PC.

6-13-3 Method of Use

The Device Monitor screen is displayed by operating the system menu as de- scribed below.

Ver 3.10

Select Expansion Mode.

Select Device Monitor.

An error message will be displayed if the wrong communications proto- col is selected.

The Device Monitor screen is displayed.

Reference: When an error screen is displayed, press the Check touch switch on the screen to return to the system menu. In addition, pressing two of the four corners of the touch panel simultaneously in the error screen enables the display of the system menu.

For more details on operations of the Device Monitor function, refer to 2-16 De- vice Monitor Function in the Reference Manual.