Setting Conditions for Communications with Host by Using Memory Switches

Section 6-7

6-7-4 Setting the NT Link (1:N) Method (Standard/High-speed)

Set the communication conditions for the NT link (1:N) method at serial port A or serial port B by following the operation from the System Menu shown below.

The communications speed determines whether the 1:N NT Link is standard or high-speed.

Standard:

Standard 1:N NT Link

High-speed:

High-speed 1:N NT Link

Ver 3.10

Select Maintenance Mode.

Select Memory Switch.

Display the fourth memory switch screen by pressing the [] (next screen) or [] (previous screen) touch switch.

Press the touch switch corresponding to the port at which the NT link (1:N) method (stan- dard or high-speed) is to be set (Comm. A Method or Comm. B Method) to display the setting option NT Link (1:N).

The setting option changes each time the touch switch is pressed.

In this example, serial port A is used.