Omron NT31 NT31C manual Commu Nication Applicable PCs Connected Port Method Type

Models: NT31 NT31C

1 296
Download 296 pages 47.55 Kb
Page 232
Image 232

Programming Console Function

 

 

Section 6-12

 

 

 

 

 

 

 

Commu-

Commu-

 

 

 

 

nication

nication

Applicable PCs

Connected Port

 

Method

Type

 

 

 

 

 

 

 

 

 

 

 

 

C200HE-CPU42-(Z)E(*1)

 

 

 

 

 

C200HG-CPU43-(Z)E(*1)

 

 

 

 

 

C200HG-CPU63-(Z)E(*1)

 

 

 

 

 

C200HX-CPU44-(Z)E(*1)

 

 

 

 

 

C200HX-CPU64-(Z)E(*1)

 

 

 

 

 

C200HX-CPU65-ZE(*1)

 

 

 

 

 

C200HX-CPU85-ZE(*1)

 

 

 

 

 

CPM2A-30CDjj-j(*1)

CPU built-in RS-232C

 

 

 

CPM2A-40CDjj-j(*1)

 

 

 

port

 

 

 

CPM2A-60CDjj-j(*1)

 

 

 

 

 

 

NT Link

 

CPM2C-10jjjjjj-j(*2)

 

 

 

 

CPM2C-20jjjjjj-j(*2)

 

 

 

(1:1)

 

CQM1-CPU4j-EV1(*1)

 

 

 

 

 

 

 

 

 

 

CQM1H-CPU21(*1)

 

 

 

 

 

CQM1H-CPU51(*1)

 

 

 

 

RS-232C

CQM1H-CPU61(*1)

 

 

 

 

SRM1-C02-V2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CPM1-10CDR-j

 

 

 

 

 

CPM1-20CDR-j

 

 

 

 

 

CPM1A-10CDj-j

Peripheral port (*3)

 

 

 

CPM1A-20CDj-j

 

 

 

 

 

 

 

 

CPM1A-30CDj-j

 

 

 

 

 

CPM1A-40CDj-j

 

 

 

 

 

 

 

 

 

 

 

CS1G-CPU42-E(V1)(*1)

 

 

 

 

 

CS1G-CPU43-E(V1)(*1)

 

 

 

 

 

CS1G-CPU44-E(V1)(*1)

 

 

 

NT Link

 

CS1G-CPU45-E(V1)(*1)

S CPU built-in

 

 

CS1H-CPU63-E(V1)(*1)

RS-232C port

 

(1:N)

 

 

 

CS1H-CPU64-E(V1)(*1)

S Peripheral port (*4)

 

 

 

 

 

 

CS1H-CPU65-E(V1)(*1)

 

 

 

 

 

CS1H-CPU66-E(V1)(*1)

 

 

 

 

 

CS1H-CPU67-E(V1)(*1)

 

 

*1: The peripheral port Programming Console always has priority. If a Programming Console is connected later, the Programming Console function of the NT31/NT31C is invalidated and operation from the NT31/NT31C becomes impossible.

*2: The CPM2C-CN111 Connecting Cable splits the PC’s Communication Port into a RS-232C port and a peripheral port.

*3: An RS-232C cable cannot be connected to the peripheral port. An RS-232C adapter (CPM1-CIF01) is required.

*4: The RS-232C cable cannot be directly connected to the peripheral port. An RS-232C converting cable (CS1W-CN118) is required.

Reference: Note that the Programming Console function cannot be used with CPM1, CQM1, and C200HX/HG/HE PCs of the following lot numbers.

CPM1: jjj5, jj*6

where * is a number in the range 1 to 9 or the letter X or Y. CQM1: jjj3, jjj4, jjj5, jj*6

where * is a number in the range 1 to 9 or the letter X or Y. C200HX/HG/HE: jjj5 jj*6

where * is a number in the range 1 to 9 or the letter X or Y.

222