Omron NT31 NT31C manual Additional Functions of the V2 Versions

Models: NT31 NT31C

1 296
Download 296 pages 47.55 Kb
Page 18
Image 18

Functions of the NT31/NT31C

Section 1-2

1-2-3 Additional Functions of the V2 Versions

 

The V2 versions of NT31/NT31C are supplemented and enhanced by the fol-

 

lowing functions.

High-speed 1:N NT Link

The V2 versions are compatible with the high-speed 1:N NT Link as well as the

 

earlier standard 1:N NT Link.

Additional Mathematical

Operands (values referenced by formula) can be registered to allow the PT to

Functions

perform calculations automatically and write the results of those calculations to

 

numeral memory tables or words in the host.

Device Monitor Function

The new device monitor function can be used to change the PC’s operating

 

mode or display/change values in the PC’s memory areas. The present values

 

(PVs) of several words can be listed with the device monitor.

Interlock Function

PT operations and inputs can be disabled from the PC if interlock bits have been

 

allocated in the PC for the corresponding PT touch switches, numeric inputs, or

 

string inputs.

Improved Lamp/Touch Switch Labels

NT30/NT30C and

NT620S/NT620C/NT625C

Emulation

Additional CS1 Data Areas Accessible

Recipe Function

The following displays can be performed with lamp or touch switch labels:

Display several lines of labels.

Switch the display between different labels when OFF and ON.

Display the numeral memory table contents as labels.

Display the string memory table contents as labels.

The word configuration of the PT status control area and PT status notify area can be set to emulate those of the NT30/NT30C or NT620S/NT620C/NT625C; this mode is called NT30/620 compatible mode.

When the PT is operating in NT30/620 compatible mode, it will be equivalent to an NT30/NT30C or NT620S/NT620C/NT625C in the functions listed below. The PT retains full V2 functionality in all functions other than the ones listed below. Refer to Appendix C in the NT31/NT31C/NT631/NT631C Programmable Termi- nal Reference Manual for more details.

Word configuration and functions of the PT status control area and PT status notify area

Image/library codes

Insertion of image/library data into character strings

Data areas in CS1 PCs that were previously inaccessible can be accessed. The data areas listed below can be accessed (read/written).

All banks in the EM area, timer completion flags (TU), counter completion flags (CU), Work areas (WR), Task flags (TK), and the HR area.

You can set the data (numeric values) for multiple words in record units using the tabular elements on the PT screen, and write these settings in a single operation to words on the host (i.e., PC or PT memory) using a touch switch operation on the PT Unit. Also, multiple words of numeric data can be read from the host in one operation. In this way, groups of parameter settings can be edited at the PT Unit, and written to or read from the host.

Adjusting Contrast and

You can display the brightness and contrast adjustment screen using either the

Brightness During PT

touch switch or commands from the host, even while the PT is in operation.

Operation

 

6